Filter Results By:

Products

Applications

Manufacturers

RF Loads

See Also: Dummy Loads


Showing results: 46 - 60 of 62 items found.

  • PXIe-4154, 2-Channel, 8 V, 3 A PXI Programmable Power Supply

    781155-01 - NI

    2-Channel, 8 V, ±3 A PXI Programmable Power Supply—The PXIe‑4154 is a specialized programmable power supply for battery simulation. It is designed to simulate a lithium‑ion battery cell’s transient speed, output resistance, and 2‑quadrant operation (source/sink). Critical to many RF and wireless applications, the simulator’s fast transient response time allows it to rapidly respond to changes in load current with minimal voltage dip, which makes the PXIe‑4154 ideal for powering devices under test (DUTs) such as RF power amplifiers, cellular handsets, and a variety of other mobile devices. To model the behavior of a battery more accurately, you can use the onboard programmable output resistance to simulate a battery’s internal resistance. For quiescent and standby current measurements, the PXIe‑4154 features integrated current measurement.

  • Analog Power Supply

    Type NPS-2412 - National RF, Inc

    National RF's Type NPS-2412 analog power supply was designed to be used in communication equipment where radiated switching inverter noise from conventional “switching type” supplies is not acceptable. The power supply consists of a standard rectified transformer output driving a pair of voltage regulators and filtering networks. The 2412 offers an adjustable voltage output between 2 and 24 volts as well as a fixed voltage output of 12 volts. A maximum of 20 Watts of DC power can be supplied from the unit. As the voltage regulators dissipate power in the regulation process, the power to the load is derated accordingly, dependent on the set voltage to the load. The adjustable regulator is a standard LM-317T integrated circuit device. The fixed regulator is a standard LM 7812 device. Upon customer request, the LM 7812 device may be changed to any voltage rating within the the LM-78xx series of regulators. Contact National RF for this modification if desired.

  • 4-in-1 OSLT Calibration Kit, DC to 50 GHz, 2.4 mm (m)

    CK564A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (m)

    CK058M - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (m) 50 Ohm

    CK520A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (f)

    CK058F - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 40 GHz, 2.92 mm (m)

    CK562A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (m) 50 Ohm

    CK518A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm

    CK521A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (f) 50 Ohm

    CK519A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • POWER ATTENUATORS

    TYPE ATF - National RF, Inc

    National RF’s Type ATF Power Attenuators were designed to allow interfacing of linear power amplifiers to RF exciters, where a specific amount of drive to the amplifier is prescribed. Often, however, drive from the RF exciter exceeds this minimum prescribed level and some form of power attenuation must be used in order to not damage the input of the power amplifier. National RF’s type ATF-3 offers 3 dB of power attenuation (1/2 of the power) when used between the exciter and the amplifier and will handle an input power of 132 Watts, RMS (continuous power) while providing about 66 Watts RMS output power, when it is terminated into 50 ohms. In practice, the ATF-3 attenuator will handle exciters achieving Peak Envelope Power levels (PEP) in the area of 200 to 250 Watts while providing half of that power to the load. For less attenuation requirements, the ATF-1 and ATF-2 offer 1 and 2 dB of attenuation, respectively.

  • PXIe High-Speed Source/Measure Unit, 13 V, ± 1 A or 6 V, ± 3 A, 18 W

    M9111A - Keysight Technologies

    The M9111A is a 1-slot, 2-quadrant PXIe module that provides stable, glitch-free sourcing and sinking, and high accuracy measurements. It offers high-throughput and measurement quality for design validation and production test of RF power amplifiers. With industry-leading output stability under extreme, dynamic load conditions and unmatched transient performance to dramatically reduce voltage droop due to pulse loading, the M9111A SMU speeds test time. The high-speed M9111A can change its output voltage, stabilize that voltage, and accurately measure current from Amps down to micro-Amps all in less than 1 ms so that you can move on to the next test as quickly as possible.

  • Digital RF Power &V.S.W.R. Indicator

    PowerMaster Series - Array Solutions

    Thank you very much for purchasing the Array Solutions PowerMaster Series RF Power/VSWR Indicator. The PowerMaster represents a breakthrough in features for measurement of the performance of your transmitting system. Microprocessor control insures fast capture time and low power consumption. With the ability to monitor your VSWR and power levels at all times, you will know that your transmitter, RF source, and load, or antenna systems are operating effectively and safely. In addition, the power and VSWR relay alarms can quickly shut down your power amplifier system and alert you to the alarm condition. This places an additional layer of protection in your transmitting system to help preserve expensive tubes and finals. The PowerMaster also features the ability to be monitored and controlled from a PC via the bundled software, and the unique ability to be monitored and controlled over a LAN or from the internet. PowerMaster firmware updates will be made available for download from the Array Solutions website as they becomeavailable. This means that the user can take full advantage of features or enhancements just by installing the firmware update. No need to return the meter to the factory for updates.

  • Automatic Calibration Module

    ACM4509 - Copper Mountain Technologies

    ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Automatic Calibration Module

    ACM2509 - Copper Mountain Technologies

    ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

Get Help